IBM System Cluster 1350 factory settings
May, 2009
The following tables show the factory settings for network addressing, user IDs, rack numbering, BladeCenter® unit and node numbering, I/O bay location numbering, and hostnames of the various IBM® System Cluster 1350™ components.
Table 1: Network addressing and hostnames
IP Address
|
Hostname
|
Component
|
172.20.0.1
|
mgt.cluster.com
|
Management node eth0 (cluster vlan)
|
172.30.0.1
|
mgt1.cluster.com
|
Management node eth1 (management vlan)
|
172.29.0.1
|
bmc
|
Management node alias eth0:1 (cluster vlan )
|
172.29.101.1*
|
bmc001
|
Node BMCs
|
172.20.1.1
|
storage001
|
Storage nodes
|
172.30.2.1*
|
triton01A
|
DS3000/DS4000 storage controllers (A, B)
|
172.20.101.1
|
node001
|
Compute nodes
|
172.40.101.1
|
hca001
|
HCA cards ib0 (cluster vlan)
|
172.20.4.1
|
user001
|
User nodes
|
172.30.10.1*
|
myri001
cis001
volt001
ql001
|
Myrinet or InfiniBand:
Voltaire 2004, 2012, 2036, 9096, 9288,4036, 4700,
QLogic 9024, 9080, 9120, 9240, 12200, 12300, 12800
|
172.30.20.1*
|
ts001
|
Terminal servers: Cyclades ACS32/ACS48
|
172.30.30.1*
|
rsa001, avocent001
|
RSA or Avocent MP5300
|
172.30.40.1*
|
cisco2960-001
|
10/100 Cisco switches
|
172.30.50.1*
|
bnt8000-001
bnt8100-001
brocb50c-001
brocb24x-001
brocfcx648
cisco3750-001
cisco4948-001
force50-001
mlnxis5030-001
smc8024-001
smc8848-001
smc8708-001
volt8500-001
|
1U/2U 1G and 10G Ethernet Switches
Blade Network Technologies 8000, 8100, 8126
Brocade Networks Netiron ZB50C(CES2048CX),
FCX648 (B48Y)
Cisco 3750, 3560, 4900M, 4948
Force10 S50, S2410
Mellanox IS5030
SMC 8848M, 8708, 8024
Voltaire 8500
|
172.30.60.1*
|
apc001
|
APC
|
172.30.70.1*
|
rcm001
|
RCM
|
172.30.80.1*
|
brocb08r-001
brocb16r-001
cisco6509-001
force150-001
force300-001
force600-001
force1200-001
force600i-001
force1200i-001
mlnxis5200-001
mlnxis5600-001
|
Enterprise Ethernet Switches
Brocade B08R (BigIron RX-8-AC), B16R (BigIron RX-16-AC)
Cisco 6509
Force10 E 600/E600i/E1200/E1200i and C150/C300
Mellanox IS5200 and
IS6500
|
172.30.85.1*
|
fc001
|
Fibre Channel switches
|
172.30.101.131*
|
mm001
|
BladeCenter management module
|
* Indicates the hard-coded IP address of the various Cluster 1350 components.
Rack name
|
Network
|
Rack number
|
Node*
|
Rack1
|
172.20
|
101
|
1 to 84
|
Rack2
|
172.20
|
102
|
1 to 84
|
Example: rack 1, node 1 = 172.20.101.1
* Node numbering increases from the bottom of the rack upward.
* BladeCenter unit node numbering increases from the bottom of the rack upward and from left to right.
Table 3: BMC IP addressing
Rack name
|
Network
|
Rack number
|
Node
|
Rack1
|
172.29
|
101
|
1 to 84
|
Rack2
|
172.29
|
102
|
1 to 84
|
Example: rack 1, node 1 = 172.29.101.1
Table 4: BladeCenter IP Addressing BC-H 8852-xxx or 8677-xxx with an advanced management module (AMM)
Network
|
Rack number
|
I/O bay location number (1-10) + BladeCenter unit number (1-6)
|
172.30*
|
101
|
1 to 10 (SM I/O bay 1 - SM I/O bay 10) + 1 to 6 BladeCenter unit number
|
172.30*
|
102
|
1 to 10 (SM I/O bay 1 - SM I/O bay 10) + 1 to 6 BladeCenter unit number
|
172.30*
|
101
|
Advanced management module* 130 + 1 to 6 BladeCenter unit number
*Advanced management modules in the same BladeCenter unit share one IP address.
|
Examples: 172.30.101.34 - the switch module fitted to I/O bay 3 in BladeCenter unit 4 of rack 1
172.30.102.46 - the switch module fitted to I/O bay 4 in BladeCenter unit 6 of rack 2
172.30.106.104 - the switch module fitted to I/O bay 10 in BladeCenter unit 4 of rack 6
172.30.106.133 - the AMM for BladeCenter unit 3 of rack 6
Network
|
Rack number
|
Rack name
|
HCA*
|
172.40
|
101
|
Rack1
|
1 to 84
|
172.40
|
102
|
Rack2
|
1 to 84
|
Example: rack 1, hca 1 = 172.40.101.1
*Host channel adapter (HCA) numbering increases from the bottom of the rack upward.
Table 6: Factory set user IDs and passwords
Hardware
|
User ID
|
Password
|
Comments
|
Avocent MP 5300
|
root
|
avocent
|
Default
|
APC switch
|
apc
|
apc
|
Default
|
ITouch terminal
|
access
|
system
|
Default
|
InReach terminal
|
InReach
|
access
|
Default
|
BNT switch
|
admin
|
admin
|
Default
|
Brocade
|
none
|
none
|
Default
|
Cyclades terminal
|
root
|
tslinux
|
Default
|
Cisco switch
|
(see Comments)
|
ibm1350
|
Press Enter for the userid prompt
|
SMC switch
|
admin
|
admin
|
Default
|
SMC 8024L2
|
admin
|
smcadmin
|
Default
|
AStT
|
(see Comments)
|
infiniti
|
Press Enter for the userid prompt
|
Fibre Channel switch
|
admin
|
password
|
Default
|
Force10
|
none
|
none
|
For priv exec, the password is force10
|
RSAs
|
USERID
|
PASSW0RD
|
The 0 in passw0rd is a zero
|
BladeCenter management module
|
USERID
|
PASSW0RD
|
The 0 in passw0rd is a zero
|
Cisco InfiniBand switch
|
admin
|
adminpass
|
Default
|
Mellanox
|
admin
|
admin
|
Default
|
QLogic InfiniBand switch
|
admin
|
adminpass
|
Default
|
Voltaire root:
|
br6000
|
|
Required for first log in (default)
|
Voltaire InfiniBand switch
|
admin
|
123456
|
Default
|
QLogic BC FC switch module
|
USERID
|
PASSW0RD
|
The 0 in passw0rd is a zero
|
Table 7: Operating system passwords
Operating system
|
USERID
|
Password
|
Management server
|
root
|
ibm1350
|
Nodes
|
admin
root
|
cluster
cluster
|
_________________________
IBM, BladeCenter and 1350 are trademarks of the IBM Corp. in the United States, other countries, or both. Other company, product, or service names may be trademarks or service names of others.
©Copyright International Business Machines Corporation 2007. All rights reserved.
US Government Users Restricted Rights – Use, duplication or disclosures restricted by GSA ADP Schedule Contract with IBM Corp.
IBM System Cluster 1350 factory settings