THE IMS1270 CIPS USER'S MANUAL (2)

Data Processing and Tools
Customizable Ion Probe Software
Version 4.0



CIPS user's manual (2) June2003 not fully documented for Image Processing, Periodic table, General Setup, Hardware setup, Other Tools
CONTENTS

end of contents

1. (Introduction) 5

2. (The [M, B] table) 5

3. (Starting the instrument) 5

4. (Checking the instrument before an analysis) 5

5. (Defining and Running an isotope analysis) 5

6. (Other Analyses) 5

7. Displaying and processing the Isotope analysis results 5

7.1 Overview 5

7.2 The curve_browser box 6

7.3 Displaying and processing the analysis results with the curve panel 7

7.4 The curve processing functions. 8

7.5 Processing the results with the isotope spreadsheet 11



7.5.1 Overview 11

7.5.2 The spreadsheet EM and Faraday corrections 13

7.5.3 The Main Spreadsheet panel 15

7.5.4 The spreadsheet computed cells 19

7.5.5 Processing a set of analysis resulting ratios 22

8. The EM Control and EM drift correction 24

8.1 Overview 24

8.2 Tools 25

8.2.1 PHA 25

8.2.1.1 previous functions 25

8.2.1.2 New functions related to EM drift 26

8.2.2 Set Thresholds for the PHA featuring routine 27

8.2.3 EM HV Adjust 27

8.2.3.1 Overview 27

8.2.3.2 Description 28

8.2.4 Overall PHA featuring, drift measurement 29

8.2.4.1 Overview 29

8.2.4.2 Em Drift Measurement Description 30

8.2.4.3 PHA Display Description 31

8.3 EM Yield drift measurement within an Isotope Analysis 31

8.4 EM Yield drift correction in the data spreadsheet 32



9. The stage Navigator (HOLDER) 32

9.1 Overview 32

9.2 The Stage Navigator panel 33

9.3 The Holder List Panel 35



10. Image Processing 36

11. TOOLS 36

11.1 Stability 37

11.2 Periodic Table 38

11.3 Setup pannels 39



11.3.1 General setup 39

11.3.2 Hardware setup 41

11.3.3 Detection Setup 42

11.3.4 Measure set_up 44

11.3.5 FCs Calibration 46

11.3.6 FCs Offset Calibration 47

11.4 Other Tools 48



11.4.1 Preferences 48

11.4.2 Vacuum synoptics 48

11.4.3 Other tools 49

12. (Appendices) 49

12.1 (Appendix 1: The EM Physical Principles) 49

12.2 (Appendix 2: The EM drift correction principles) 49

12.3 (Appendix 3: The QSA effect) 49

12.4 (Appendix 4: The Faraday cup Measurement principle) 49

12.5 (Appendix 5: Fundamental of Statistics) 49

12.6 (Appendix 6: LabVIEW® graph options and graph cursors) 49


end of contents
Contents

1.(Introduction)


See The IMS 1270 CIPS user's guide (1)

2. (The [M, B] table)


See The IMS 1270 CIPS user's guide (1)

3.(Starting the instrument)


See The IMS 1270 CIPS user's guide (1)

4.(Checking the instrument before an analysis)


See The IMS 1270 CIPS user's guide (1)

5.(Defining and Running an isotope analysis)


See The IMS 1270 CIPS user's guide (1)

6.(Other Analyses)


See The IMS 1270 CIPS user's guide (1)

Contents

7.Displaying and processing the Isotope analysis results

7.1Overview


When clicking on the main bar menu DATA PAGING, both the curve_browser box and the curve panel are displayed.

the curve_browser box allows to select the current analysis or any previous analysis file name.

The curve panel allows to display and to process any set of curves (Y1(X),..., Ym(X), ...) where Y1,... Ym, ... are the signals measured within an analysis and corresponding to the different species defined in the analysis species table (see the section § The SPECIES table box)

7.2The curve_browser box



This box is attached to the Curve panel. It allows to load the current analysis or any previous analysis file name in the Curve display window.






FILE CONDITIONS/CURRENT CONDITIONS both selections are equivalent if READ ACQUISITION or DISPLAY ACQUISITION is selected in the left side field below. In the other case (selection of READ FILE or DISPLAY FILE), it allows to display the data of a previous analysis file with the current graphic conditions (scale, curve selection etc...) or with the current spreadsheet conditions (computed ratios, correction...)
READ ACQUISITION/ DISPLAY ACQUISITION/ READ FILE/ DISPLAY FILE According to the selection READ/DISPLAY, the curve or the spreadsheet window will be selected and opened. According to the selection ACQUISITION/FILE, the current acquisition or a previous acquisition file will be loaded. WARNING: If NONAME is selectected in the next field, no file box will be opened for selecting a file.
ISOTOPE/HIGH RESOLUTION... Filters the analysis filename wich will be proposed for being displayed.